Data Center & AI Power

Power distribution engineered for the AI and hyperscale era

Compute is scaling faster than the grid that feeds it. NextGen RPP delivers high-density Remote Power Panels, intelligent branch-circuit monitoring, and UL 891 switchgear built to keep colocation, hyperscale, and AI training facilities energized — deployed on a timeline that keeps pace with your buildout.

Start Your Project
NX Series Remote Power Panel deployed in a data center white space
Density Without Compromise

More power per square foot of white space

Every rack you can't power is revenue you can't book. The NX Series RPP packs up to 84 single-pole branch positions and a 600A main input into a footprint engineered for the floor — freeing white space for the racks, GPUs, and cooling that actually generate value.

  • Main input up to 600A, 100% rated LSI electronic trip
  • Up to 84 single-pole branch positions, 20A–150A breakers
  • Free-standing, wall-mounted, or back-to-back configurations
  • Top and bottom cable entry for clean overhead or underfloor routing
Configure Your Panel
Built for What's Next

Key advantages for high-density facilities

Next Gen power distribution, designed around the demands of AI and hyperscale growth.

Built for What's Next

Engineered for rising rack densities and the unpredictable load profiles of AI training and inference workloads.

Rapid Deployment

Standard configurations in stock now, 4-week build-to-spec standard, and emergency/expedited options to support rapid expansion.

UL Listed

UL Listed equipment, Siemens Approved OEM, Made in the USA, and BABA-compliant for federal and infrastructure projects.

Premium Components

Quality breakers, busbar, and metering built to run continuously at 100% rated load in mission-critical environments.

Scalable & Configurable

Voltage, breaker, and enclosure options that flex from a single colocation hall to a multi-megawatt hyperscale campus.

Engineering Support

Work directly with our team on layouts, SCCR coordination, and seismic requirements before a single panel ships.

NX Intelligent BCMS branch-circuit monitoring touchscreen
Per-Circuit Visibility

NX Intelligent BCMS for real capacity planning

You can't plan capacity you can't see. NX Intelligent BCMS delivers true-RMS metering at every branch circuit, so operators know exactly how much headroom remains in each panel, each phase, and each row — turning stranded capacity into deployable capacity.

  • ±0.5% true-RMS current, voltage, energy, and power-quality data
  • Local touchscreen plus remote access for NOC and DCIM integration
  • DIN-rail modular and scalable to match panel build-out
  • Closed-door operation for safer, faster routine monitoring
Talk to Engineering

600A

Main Input

Up to 600A main with 100% rated LSI electronic trip for dense, continuous loads.

84

Branch Positions

Up to 84 single-pole positions per panel to feed more racks per footprint.

4-Week

Build-to-Spec

Standard lead time, with stock configurations and expedited options for rapid expansion.

Technical Specifications

NX Series RPP at a glance

Configured for mission-critical data center and AI infrastructure.

ModelsNX-225, NX-400, NX-600
Current Range225A–600A, 480V max
Main RatingUp to 600A, 100% rated LSI
SCCR14 kAIC @ 480VAC standard, 65 kAIC optional
Branch PositionsUp to 84 single-pole, 20A–150A breakers
Voltages415Y/240 standard; 480Y/277 & 208Y/120 optional; 3-phase Wye 4-wire, 60 Hz
ConfigurationsFree-standing, wall-mounted, back-to-back
EnclosureIndoor UL Type 1; NEMA 3R outdoor available
ReliabilitySeismic tested; top & bottom cable entry
Where We Deploy

Power for every kind of compute facility

One platform, scaled from edge sites to hyperscale campuses.

Outdoor-rated NX Switchgear for data center campus
Upstream of the Rack

NX Switchgear ties the whole campus together

When the buildout grows past the panel, NX Switchgear carries the load. UL 891 low-voltage switchgear from 400A to 4000A, rated for indoor and outdoor service, gives you a single-source path from utility service entrance to the row.

  • UL 891 low-voltage switchgear, 400A–4000A
  • Indoor and outdoor (NEMA 3R) configurations
  • Coordinated SCCR and protection across the lineup
  • Single-source RPP, BCMS, and switchgear from one U.S. manufacturer
Plan Your Lineup
Deploy With Confidence

Certified, sourced, and supported in the USA

UL Listed

Listed equipment built and tested to recognized safety standards.

Siemens Approved OEM

Built with premium, approved components for proven reliability.

Made in the USA

Manufactured domestically with responsive lead times.

BABA-Compliant

Meets Build America, Buy America requirements for infrastructure projects.

Supporting rapid expansion — a better way to deploy power.

Request a Quote

Deploy power on a timeline that keeps pace with compute

From a single colocation hall to a multi-megawatt AI campus, NextGen RPP delivers the panels, monitoring, and switchgear your buildout needs — built for what's next.

Start Your Project